Browse all practice questions for the NEIEP Machine Room Maintenance (550) Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

NEIEP Machine Room Maintenance (550) Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Dash pot overload fluid replacement should be done only with manufacturer recommended types.
  • An _______ or _______ glass can be used to view the oil level in a sleeve bearing.
  • Which item is NOT one of the three important specifications of fuses?
  • Brake operation should be checked for proper _______ and _______.
  • Dash pot overloads should trip almost immediately if tested with the _______ removed.
  • Always check the manufacturers specifications when lubricating the brake solenoid.
  • Grease lubricated open bearings require frequent lubrication.
  • Which of the following can result if too much grease is forced into a shielded bearing?
  • Which describes the correct approach to testing an energized circuit?
  • You can replace a fuse with a higher current capacity fuse.
  • A _______ can be used to determine the clearance between the armature and the pole pieces.
  • Is cleaning hoist ropes with a rag that has been soaked in an approved cleaning fluid acceptable?
  • With a given AC input voltage, which rectifiers produce a higher DC output voltage than selenium rectifiers?
  • Which interval is used for the 125% load test on brakes?
  • In an electronic selector system, which term denotes the value stored in memory that represents the exact floor location?
  • When cleaning, _______ should be kept away from the commutator and brushes.
  • What should you do with the parts cabinet and stock parts that are frequently replaced?
  • The _______ supplies DC power to areas of the system that require it, such as fields, brakes and relays.
  • An anti-static ground wrist strap should be worn during maintenance operations to protect sensitive components from static discharge.
  • Which of the following is a common sign to inspect on relay contacts?
  • It is important to seat the brushes so that there is good _______ between the brushes and the commutator.
  • When handling PCBs, avoid touching which feature to minimize damage?
  • Which statement best supports timely handling of customer complaints?
  • To prevent rotation of components that extend through the controller board when tightening connections, you should use what?
  • Motor and generator components must be _______ from each other before testing with a megger.
  • What is the proper practice when inspecting field pole pieces for signs of wear or damage?
  • Never pass a solid-state board to another person unless _______ are wearing anti-static wrist straps.
  • In a system with an electronic selector, which term describes the stored value representing the exact floor location?
  • Two materials used in the composition of sleeve bearings is _______ and _______.
  • Selectable overloads should never be placed in the manual reset position.
  • What preparation is recommended before megger insulation testing on motor and generator components?
  • Excessive grease can cause a bearing to _______ than normal.
  • Select the statement that correctly describes a selector's role.
  • The device that prevents two opposite functioning relays from closing at the same time is called a _______.
  • Which action is recommended when lubricating brake solenoids?
  • What condition in rotating machinery is described by a gap between a shaft and bearing race that allows axial movement?
  • Around rotating equipment, which items should you avoid wearing?
  • What dictates items to be serviced and their frequency?
  • Which statement about field pole pieces in a generator is true?
  • Which statement about verifying voltage level and polarity before testing is true?
  • Which action should you take regarding coordinating with building personnel when working on a jobsite?
  • What is a recommended practice for organizing frequently replaced parts?
  • Contactor air gap should be adjusted in which two states?
  • When replacing a capacitor, which rating must be met or exceeded?
  • The brake is required by code to hold 125% of the rated load. This testing should occur at _______ intervals.
  • To prevent movement of the car during overload testing the _______ leads should be removed.
  • Which practice directly supports safe and efficient machine operation by keeping areas organized and clean?
  • The approved method of troubleshooting an energized circuit involves a meter lead permanently attached to a reference and the other lead probing the circuitry.
  • Bearing friction and wear can be reduced through proper lubrication.
  • The large amount of current used to achieve full brake pick is needed to overcome the _______ forces of the brake _______.
  • _______ and _______ straight-line prints for orderly access to various electrical circuits.
  • Which statement about carbon dust in electrical equipment is true?
  • Dirty oily rags should be stored in an airtight plastic.
  • It should not be attempted to pump grease into a sealed bearing.
  • Capacitors can store lethal voltages for days after power is removed.
  • The statement that cleaning and lubrication can be performed with the MG set running is _______.
  • Oil is carried to the shaft in a sleeve type bearing by a _______ or _______.
  • The machine room should be equipped with adequate _______ and _______.
  • Is it true that attending to minor customer complaints can usually be postponed?
  • Which statement about status updates during problem resolution is correct?
  • Thermal cycling of resistor connections can cause which failure mode?
  • Heat, vibration, age and corrosive atmosphere can cause insulation to develop a _______ path to ground.
  • Sleeve bearing oil should be changed at least annually or if it becomes cloudy.
  • The frequency that armature and field connections should be checked for tightness is at least _______.
  • What guidelines should be followed when servicing or cleaning a solid state motor drive system?
  • Where are most high current and high voltage operations of a motor-generator set performed?
  • Armature connections are commonly made of which metal to enable current transfer while providing malleability?
  • Relays and their contacts operate in a routine depicted on which type of diagrams?
  • Maintenance frequency and the exact procedures vary by manufacturer and the duty of the equipment.
  • Even though defective solid-state boards should be treated as if they were _______.
  • When an electronic selector is used a _______ representing the exact location of the floor is stored in memory.
  • A counterweight governor and safeties must be installed whenever there is _______ below the hoistway.
  • Brush holders should be evenly _______ or _______ around the commutator.
  • During cleaning, solvents should be kept away from the commutator and brushes. Which option reflects this practice?
  • Good housekeeping can help you to discover defects before they become problems.
  • Electrical neutral is adjusted by shifting the _______ location with respect to the _______.
  • A _______ is used to check for insulation breakdown in armatures and fields.
  • Printed circuit boards should be handled by their _______.
  • Polarity must be identified before connecting test leads. Which statement is true?
  • After power is removed, large capacitors should be checked for stored what?
  • Every job should be equipped with an approved first aid kit, MSDS, emergency phone numbers, and type ABC Fire extinguisher.
  • Is it important to show willingness to the customer to provide premium elevator service?
  • Which statement correctly describes how increased voltage affects brake decay time?
  • What term describes the electrical interaction between the brushes and the commutator?
  • Which statement best describes the role of field pole pieces?
  • Which action best supports safe handling of carbon dust in the machine room?
  • Before megger testing, the circuit components should be _______ from the power supply.
  • Is it true that silicon rectifiers produce higher DC output voltage than selenium rectifiers for the same AC input?
  • The minimum insulation resistance between windings and ground is 0.5 megohms.
  • What should be verified about voltage level and polarity before performing maintenance?
  • Which function is typically controlled by a selector in elevator control systems?
  • What is the primary purpose of keeping straight-line prints for electrical circuits?
  • The statement 'Cleaning and lubrication can be performed with the MG set running' is false. Which option completes this?
  • A selector is a mechanically or electrically driven device that initiates or controls the following functions:
  • The presence of bronze fillings in gearcase oil can indicate wear of which components?
  • A healthy electrolytic capacitor shows high resistance on a low-ohm meter test.
  • Which hazards should be mitigated to protect work areas?
  • A _______ can be used to determine the clearance between the armature and the pole pieces.
  • In a brush holder arrangement, what pattern around the commutator ensures even wear?
  • Ground lights should be tested and kept in working condition. Which statement is true?
  • Power resistors used in controllers are wound with which conductor and made of which material to withstand high temperatures?
  • Connections on power resistors can loosen due to repeated _______ cycling.
  • Leaving elevator keys in the control station is recommended.
  • Which device is commonly used to deliver lubricant to the bearing surfaces in sleeve-type bearings?
  • Which item is not listed as part of the approved equipment needed on every job?
  • If the seals on a governor are missing it is necessary to _______ the governor.
  • The _______ or walking beam is used to prevent two opposite functioning relays from closing at the same time.
  • Under ideal conditions the resistance between ground and the armature windings should be near _______.
  • Should the customer be kept aware of the status of a problem?
  • Before servicing the governor, _______ and _______ the main line disconnect.
  • Ground lights are primarily used to indicate the grounding status of equipment. Which statement is true?
  • Improper brush tension can cause both _______ and _______ wear.
  • Which statement is true about anti-static wrist straps?
  • Operating speed is one of the key fuse specifications. What does it describe?
  • Which statement about voltage level and polarity testing is true?
  • Which statement about seating brushes is correct?
  • Shunt wires on relays often fail because they move every time the relay energizes and de-energizes.
  • The extent of machine room maintenance required is related to the _______, _______, and _______ of equipment.
  • What is a safe approach to removing carbon dust from equipment interior?
  • What term describes placing a tag on a disconnect to indicate it is out of service?
  • Fuses used to protect sensitive solid state circuits are required to be ______ types.
  • To prevent rotation of devices that extend through the controller board _______ when tightening their connections.
  • Capacitors in control circuits may retain dangerous voltages after power is removed, making it important to discharge capacitors before servicing.
  • Dash pot overloads should trip almost immediately if tested with the fluid removed.
  • If the voltage applied to brake coil is increased the brake decay time will increase.
  • Measure and record the brake spring dimensions before disassembly.
  • Which term best describes the router mechanic's relation to the customer?
  • Can contactors be safely operated for test purposes without their arc barriers in place?
  • The statement 'All power supplies used in a solid state motor drive are highly filtered and regulated' is
  • Which materials are used for the winding and casing of power resistors to withstand high temperatures?
  • What is a likely consequence of inadequate lubrication for bearings?
  • All power supplies used in a solid state motor drive are highly filtered and regulated.
  • Compared with ball bearings, sleeve bearings typically exhibit what characteristic?
  • A _______ can result if too much grease is forced into a shielded bearing.
  • Which statement about maintenance of field pole pieces is accurate?
  • Which type of controllers can radiate excessive heat and noise?
  • Two Types of governors are _______ and _______.
  • Sealed bearings require lubrication bi-annually.
  • The movement of the selector is _______ to the movement of the elevator car.
  • As the elevator begins to accelerate through the partially set brake the controller sends full _______ to the brake coil to pick it fully.
  • Follow your company's approved Lock out Tag out procedure.
  • A thermal overload uses a _______ strip to activate a contact that opens a circuit and removes power to the motor.
  • The frequency of maintenance operation and the exact procedures vary by manufacture and the duty of the equipment.
  • The statement 'A relay selector is commonly used on high-speed high-rise traction elevators' is true or false?
  • Grease lubricated open bearings require frequent lubrication.
  • Cleaning and lubrication are two important duties of the elevator maintenance mechanic.
  • An open ball or roller bearing can receive grease from _______
  • Wear safety glasses at all times.
  • In the eyes of the customer, the router mechanic represents which entity?
  • Sand asbestos brake pads to remove glazing and contamination from oil or grease.
  • Which type of bearing has the highest coefficient of friction?
  • Which instrument is used to check insulation resistance in armatures and fields?
  • Before greasing a bearing with a grease gun remove the _______.
  • An _______ or _______ glass can be used to view the oil level in a sleeve bearing.
  • Which safety practice around rotating equipment is correct?
  • Mechanical selectors are driven by a _______ or _______.
  • A low ohmmeter reading of an electrolytic capacitor is an indication it is bad.
  • A _______ can be used to view the oil level in a sleeve bearing.
  • Which statement about ground lights in electrical equipment is true?
  • Current carrying members of armature connections are _______ and tend to stretch and loosen.
  • Which type of bearing wears silently without warning of failure?
  • Leave keys in the car station that control the operation of the elevator.
  • Where should visits to the job site for reported problems be documented?
  • Printed circuit boards removed from their sockets can be more easily damaged by _______ than those installed.
  • Loss of exciter output or voltage reversal can result from _______ at the brushes.
  • The oil level in a geared machine should be maintained at _______.
  • When leaving or completing a job, what should you do with building personnel?
  • What condition can cause insulation to develop a path to ground?
  • The controller delivers full current to the brake coil during acceleration to ensure full pickup.
  • True or False: Use emery paper to seat brushes.
  • There should be no visible _______ in a hoist motor shaft of a geared machine during acceleration and deceleration.
  • It should not be attempted to pump grease into a _______
  • Which of the following is true about anti-static precautions?
  • Following proper safety procedures should be practiced on a daily basis.
  • The presence of _______ in the gearcase oil can be an indication of a problem.
  • A relay selector is commonly used on high-speed high-rise traction elevators.
  • Which statement about carbon dust in electrical equipment is accurate?
  • Proper neutral setting important to keep _______ at a minimum.
  • Which factor is minimized by proper neutral setting in motor drive systems?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy